SEER2 Requirements by State: Federal Minimums for Air Conditioners and Heat Pumps (2026)
- Primary data
- 10 CFR 430.32(c) (eCFR) and ACS 2025 1-year table B25003
- Data period
- Standards in force 2026-11-02; households 2025
- Latest release used
- 2026-10-29
- Next release
- ACS 2026 1-year expected in 2027; eCFR updated daily
- Geography
- 50 states and DC
- Sources
- 32 (31 Tier 1)
SEER2 requirements by state follow three federal regions: 53.0% of US households (ACS 2025) live in the 21 Southern jurisdictions where a split air conditioner must reach 14.3 SEER2 (13.8 at 45,000 Btu/h and up) at installation. The 30 Northern states require 13.4 SEER2. Split heat pumps need 14.3 SEER2 and 7.5 HSPF2 nationwide.
SEER2 requirements by state: federal minimums registry
Checked Checked once for this edition; rechecked when DOE amends 10 CFR 430.32 and at least every six months. Last checked 2026-11-02. Entries are neutral records of public data; each links to its source record.
| State | Region and minimums coded from 10 CFR 430.32(c) | Date | Evidence | Source |
|---|---|---|---|---|
| Alabama | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Alaska | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Arizona | Southwest. Split AC 14.3 SEER2 and 11.7 EER2 under 45,000 Btu/h, 13.8 SEER2 and 11.2 EER2 at 45,000+ (9.8 EER2 at 15.2 SEER2+); packaged AC 10.6 EER2 (at installation). 10 CFR 430.32(c)(5) to (6); install records 48 months. No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Arkansas | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| California | Southwest. Split AC 14.3 SEER2 and 11.7 EER2 under 45,000 Btu/h, 13.8 SEER2 and 11.2 EER2 at 45,000+ (9.8 EER2 at 15.2 SEER2+); packaged AC 10.6 EER2 (at installation). 10 CFR 430.32(c)(5) to (6); install records 48 months. No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Colorado | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Connecticut | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Delaware | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| District of Columbia | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Florida | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Georgia | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Hawaii | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Idaho | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Illinois | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Indiana | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Iowa | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Kansas | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Kentucky | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Louisiana | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Maine | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Maryland | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Massachusetts | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Michigan | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Minnesota | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Mississippi | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Missouri | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Montana | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Nebraska | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Nevada | Southwest. Split AC 14.3 SEER2 and 11.7 EER2 under 45,000 Btu/h, 13.8 SEER2 and 11.2 EER2 at 45,000+ (9.8 EER2 at 15.2 SEER2+); packaged AC 10.6 EER2 (at installation). 10 CFR 430.32(c)(5) to (6); install records 48 months. No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| New Hampshire | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| New Jersey | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| New Mexico | Southwest. Split AC 14.3 SEER2 and 11.7 EER2 under 45,000 Btu/h, 13.8 SEER2 and 11.2 EER2 at 45,000+ (9.8 EER2 at 15.2 SEER2+); packaged AC 10.6 EER2 (at installation). 10 CFR 430.32(c)(5) to (6); install records 48 months. No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| New York | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| North Carolina | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| North Dakota | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Ohio | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Oklahoma | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Oregon | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Pennsylvania | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Rhode Island | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| South Carolina | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| South Dakota | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Tennessee | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Texas | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Utah | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Vermont | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Virginia | Southeast. Split AC 14.3 SEER2 under 45,000 Btu/h, 13.8 at 45,000+ (at installation); heat pumps and packaged units at national floors. 10 CFR 430.32(c)(5) to (6); install records 48 months (10 CFR 429.142). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Washington | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| West Virginia | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Wisconsin | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
| Wyoming | North. Split AC 13.4 SEER2 (by manufacture date); split heat pump 14.3 SEER2 / 7.5 HSPF2; packaged AC 13.4 SEER2; packaged heat pump 13.4 SEER2 / 6.7 HSPF2. 10 CFR 430.32(c)(5). No stricter state standard found. Confidence: clear text | 2023-01-01 | agency record | Record |
SEER2 requirements by state come from three federal regions, not 51 state rules
Every state's SEER2 minimum is set by one federal regulation, 10 CFR 430.32(c), which sorts the 50 states and DC into a North, a Southeast and a Southwest region. Only air conditioners change with the region; heat pumps carry one national floor.
The base national standard for a split-system air conditioner made on or after January 1, 2023 is 13.4 SEER2, for both capacity classes (10 CFR 430.32(c)(5), read 2026-11-02). That base standard is the whole rule in the 30 Northern states.
In the Southeast (16 states plus DC) and the Southwest (Arizona, California, Nevada and New Mexico), a split air conditioner installed on or after January 1, 2023 must reach 14.3 SEER2 below 45,000 Btu/hr of certified cooling capacity and 13.8 SEER2 at 45,000 Btu/hr and up (10 CFR 430.32(c)(6)).
The Southwest adds a peak-heat test. A split air conditioner there also needs 11.7 EER2 below 45,000 Btu/hr and 11.2 EER2 above it, falling to 9.8 EER2 once its certified SEER2 is 15.2 or more; a packaged air conditioner needs 10.6 EER2 (10 CFR 430.32(c)(6)).
| Product class (metric) | North (30 states) | Southeast (16 states + DC) | Southwest (4 states) | What the date test keys on |
|---|---|---|---|---|
| Split AC, under 45,000 Btu/h (SEER2) | 13.4 | 14.3 | 14.3 | Installation date (South); manufacture date (North) |
| Split AC, 45,000 Btu/h and up (SEER2) | 13.4 | 13.8 | 13.8 | Installation date (South); manufacture date (North) |
| Split AC, EER2 | none | none | 11.7 under 45k, 11.2 at 45k+; 9.8 if SEER2 is 15.2+ | Installation date |
| Split heat pump (SEER2 / HSPF2) | 14.3 / 7.5 | 14.3 / 7.5 | 14.3 / 7.5 | Manufacture date |
| Packaged AC (SEER2) | 13.4 | 13.4 | 13.4 | Manufacture date; Southwest EER2 at installation |
| Packaged AC, EER2 | none | none | 10.6 | Installation date |
| Packaged heat pump (SEER2 / HSPF2) | 13.4 / 6.7 | 13.4 / 6.7 | 13.4 / 6.7 | Manufacture date |
| Small-duct high-velocity (SEER2 / HSPF2) | 12 / 6.1 | 12 / 6.1 | 12 / 6.1 | Manufacture date |
| Space-constrained AC / heat pump (SEER2; HSPF2) | 11.7 / 11.9; 6.3 | 11.7 / 11.9; 6.3 | 11.7 / 11.9; 6.3 | Manufacture date |
10 CFR 430.32(c)(5) to (6), read 2026-11-02. Southwest EER2 values at 95 F outdoor.
Source: [1] Office of the Federal Register / U.S. Department of Energy
13.4 = North (checked by manufacture date); 14.3 = Southeast or Southwest (checked at installation; Southwest also has EER2 floors)
Source: 10 CFR 430.32(c)(5) to (6), eCFR read 2026-11-02. HVAC Business Brokers Research Desk.
Central air conditioner (as regulated here): A single-phase, air-cooled air conditioner or heat pump rated below 65,000 Btu per hour, whether a single-package unit or a split system (10 CFR 430.2). Three-phase and larger units are commercial equipment under a different part of the rules.
For an HVAC owner the region decides which equipment a shop can stock and install. A business that works across a regional line, such as a Delaware shop serving Pennsylvania customers, is working under two split air conditioner floors.
53.0% of US households live where the air conditioner floor is checked at installation
The regional standard covers a majority of homes. Summing 2025 American Community Survey households by DOE region shows 71.1 million of 134.1 million households, 53.0%, in the 21 jurisdictions where a split air conditioner must meet the higher regional SEER2 floor on the day it is installed.
The Southeast holds 52.1 million households (38.8% of the US total), the Southwest 19.0 million (14.2%) and the North 63.0 million (47.0%), according to ACS 2025 1-year table B25003, released 2026-10-29.
Counting owner-occupied homes only, 45.8 million households, or 52.3% of the 87.5 million owner-occupied households in the 50 states and DC, are in the two regional zones.
Weighting each region's legal floor by its households gives a national average minimum of 13.88 SEER2 for a split air conditioner under 45,000 Btu/hr in 2025. That figure averages rules, not equipment: actual installs run above the floor.
| Region | Jurisdictions | Households 2025 | Households (millions) | Share of US households (%) | Owner-occupied 2025 | Share of owner-occupied (%) |
|---|---|---|---|---|---|---|
| North | 30 | 62952423 | 63.0 | 47.0 | 41700870 | 47.7 |
| Southeast | 17 | 52062729 | 52.1 | 38.8 | 34679200 | 39.6 |
| Southwest | 4 | 19048270 | 19.0 | 14.2 | 11131664 | 12.7 |
| Southeast + Southwest | 21 | 71110999 | 71.1 | 53.0 | 45810864 | 52.3 |
| United States (50 states + DC) | 51 | 134063422 | 134.1 | 100.0 | 87511734 | 100.0 |
ACS 2025 1-year, table B25003; region from 10 CFR 430.32(c)(6). Puerto Rico excluded.
Source: [30][1] U.S. Census Bureau; Office of the Federal Register / U.S. Department of Energy
Owner-occupied and renter-occupied households, 50 states and DC
Source: U.S. Census Bureau, ACS 2025 1-year, table B25003; regions from 10 CFR 430.32(c)(6).
California, Texas and Florida, the three largest states by households, all sit in a regional zone: California has 13.9 million households, Texas 11.6 million and Florida 9.3 million (ACS 2025).
Highlighted: Southeast (SE) or Southwest (SW), where split AC floors are checked at installation
Source: U.S. Census Bureau, ACS 2025 1-year, table B25003; regions from 10 CFR 430.32(c)(6).
Show all 51 rows
| Rank | State | DOE region | Households 2025 | Share of US households (%) | Split AC minimum SEER2 (under 45k / 45k+) | Split AC date test |
|---|---|---|---|---|---|---|
| 1 | California | Southwest | 13898622 | 10.37 | 14.3 / 13.8 | Installation |
| 2 | Texas | Southeast | 11607274 | 8.66 | 14.3 / 13.8 | Installation |
| 3 | Florida | Southeast | 9326796 | 6.96 | 14.3 / 13.8 | Installation |
| 4 | New York | North | 7867612 | 5.87 | 13.4 | Manufacture |
| 5 | Pennsylvania | North | 5405581 | 4.03 | 13.4 | Manufacture |
| 6 | Illinois | North | 5134283 | 3.83 | 13.4 | Manufacture |
| 7 | Ohio | North | 4957873 | 3.70 | 13.4 | Manufacture |
| 8 | North Carolina | Southeast | 4539531 | 3.39 | 14.3 / 13.8 | Installation |
| 9 | Georgia | Southeast | 4269857 | 3.18 | 14.3 / 13.8 | Installation |
| 10 | Michigan | North | 4150990 | 3.10 | 13.4 | Manufacture |
| 11 | New Jersey | North | 3565008 | 2.66 | 13.4 | Manufacture |
| 12 | Virginia | Southeast | 3480219 | 2.60 | 14.3 / 13.8 | Installation |
| 13 | Washington | North | 3180129 | 2.37 | 13.4 | Manufacture |
| 14 | Arizona | Southwest | 3040935 | 2.27 | 14.3 / 13.8 | Installation |
| 15 | Tennessee | Southeast | 2954096 | 2.20 | 14.3 / 13.8 | Installation |
| 16 | Massachusetts | North | 2827794 | 2.11 | 13.4 | Manufacture |
| 17 | Indiana | North | 2816686 | 2.10 | 13.4 | Manufacture |
| 18 | Missouri | North | 2604619 | 1.94 | 13.4 | Manufacture |
| 19 | Wisconsin | North | 2567583 | 1.92 | 13.4 | Manufacture |
| 20 | Colorado | North | 2483142 | 1.85 | 13.4 | Manufacture |
| 21 | Maryland | Southeast | 2428843 | 1.81 | 14.3 / 13.8 | Installation |
| 22 | Minnesota | North | 2391870 | 1.78 | 13.4 | Manufacture |
| 23 | South Carolina | Southeast | 2296350 | 1.71 | 14.3 / 13.8 | Installation |
| 24 | Alabama | Southeast | 2070835 | 1.54 | 14.3 / 13.8 | Installation |
| 25 | Kentucky | Southeast | 1885581 | 1.41 | 14.3 / 13.8 | Installation |
| 26 | Louisiana | Southeast | 1855847 | 1.38 | 14.3 / 13.8 | Installation |
| 27 | Oregon | North | 1745361 | 1.30 | 13.4 | Manufacture |
| 28 | Oklahoma | Southeast | 1616177 | 1.21 | 14.3 / 13.8 | Installation |
| 29 | Connecticut | North | 1456915 | 1.09 | 13.4 | Manufacture |
| 30 | Iowa | North | 1355504 | 1.01 | 13.4 | Manufacture |
| 31 | Arkansas | Southeast | 1277805 | 0.95 | 14.3 / 13.8 | Installation |
| 32 | Nevada | Southwest | 1245703 | 0.93 | 14.3 / 13.8 | Installation |
| 33 | Utah | North | 1208124 | 0.90 | 13.4 | Manufacture |
| 34 | Kansas | North | 1205638 | 0.90 | 13.4 | Manufacture |
| 35 | Mississippi | Southeast | 1197317 | 0.89 | 14.3 / 13.8 | Installation |
| 36 | New Mexico | Southwest | 863010 | 0.64 | 14.3 / 13.8 | Installation |
| 37 | Nebraska | North | 827249 | 0.62 | 13.4 | Manufacture |
| 38 | Idaho | North | 765200 | 0.57 | 13.4 | Manufacture |
| 39 | West Virginia | North | 747801 | 0.56 | 13.4 | Manufacture |
| 40 | Maine | North | 620759 | 0.46 | 13.4 | Manufacture |
| 41 | New Hampshire | North | 574089 | 0.43 | 13.4 | Manufacture |
| 42 | Hawaii | Southeast | 500883 | 0.37 | 14.3 / 13.8 | Installation |
| 43 | Montana | North | 481275 | 0.36 | 13.4 | Manufacture |
| 44 | Rhode Island | North | 450467 | 0.34 | 13.4 | Manufacture |
| 45 | Delaware | Southeast | 422123 | 0.31 | 14.3 / 13.8 | Installation |
| 46 | South Dakota | North | 387580 | 0.29 | 13.4 | Manufacture |
| 47 | North Dakota | North | 352013 | 0.26 | 13.4 | Manufacture |
| 48 | District of Columbia | Southeast | 333195 | 0.25 | 14.3 / 13.8 | Installation |
| 49 | Vermont | North | 285750 | 0.21 | 13.4 | Manufacture |
| 50 | Alaska | North | 278920 | 0.21 | 13.4 | Manufacture |
| 51 | Wyoming | North | 256608 | 0.19 | 13.4 | Manufacture |
ACS 2025 1-year B25003; minimums from 10 CFR 430.32(c)(5) to (6).
Source: [30][1] U.S. Census Bureau; Office of the Federal Register / U.S. Department of Energy
For a contractor, the share matters because the installation test applies to every replacement job in those 21 jurisdictions, not only new construction.
13.4 SEER2 is not a lower bar than 14 SEER: DOE changed the test, then restated the floors
SEER2 numbers look smaller because the test got harder, not because the standard got weaker. DOE wrote the 2023 floors on the old test first (14, 15 and 14.5 SEER) and then translated them into the new appendix M1 metrics (13.4, 14.3 and 13.8 SEER2).
The 2017 direct final rule (82 FR 1786, Table I-1) lists the 2023 standards on the pre-2023 test: 14 SEER for a split air conditioner nationally, 15 SEER under 45,000 Btu/h and 14.5 SEER at 45,000 Btu/h and up in the South, and 15 SEER and 8.8 HSPF for a split heat pump.
The codified rule states the same levels as 13.4, 14.3 and 13.8 SEER2 and 7.5 HSPF2. DOE wrote that its translations "do not assume nor reflect any change to product design" and reported a 15% reduction from HSPF to HSPF2 for split and packaged heat pumps (82 FR 1786).
| Standard level | Old test (pre-2023) | Appendix M1 (2023 on) | Implied ratio |
|---|---|---|---|
| Split AC, national (both sizes) | 14 SEER | 13.4 SEER2 | 0.957 |
| Split AC under 45,000 Btu/h, Southeast and Southwest | 15 SEER | 14.3 SEER2 | 0.953 |
| Split AC 45,000 Btu/h and up, Southeast and Southwest | 14.5 SEER | 13.8 SEER2 | 0.952 |
| Split heat pump, cooling | 15 SEER | 14.3 SEER2 | 0.953 |
| Split heat pump, heating | 8.8 HSPF | 7.5 HSPF2 | 0.852 |
| Packaged AC and packaged heat pump, cooling | 14 SEER | 13.4 SEER2 | 0.957 |
| Packaged heat pump, heating | 8.0 HSPF | 6.7 HSPF2 | 0.838 |
| Split AC under 45,000 Btu/h, Southwest | 12.2 EER | 11.7 EER2 | 0.959 |
| Split AC 45,000 Btu/h and up, Southwest | 11.7 EER | 11.2 EER2 | 0.957 |
| Split AC, Southwest, high-SEER units | 10.2 EER | 9.8 EER2 | 0.961 |
| Packaged AC, Southwest | 11.0 EER | 10.6 EER2 | 0.964 |
Old-test levels from 82 FR 1786 Table I-1; M1 levels from 10 CFR 430.32(c)(5) to (6). Ratio computed by the HVAC Business Brokers Research Desk.
Source: [14][1] U.S. Department of Energy (Federal Register); Office of the Federal Register / U.S. Department of Energy
2023 federal floors
Source: 82 FR 1786 Table I-1; 10 CFR 430.32(c)(5) to (6).
Measured on the old test, the 2023 step raised split air conditioners by about one SEER point and left packaged units alone
Putting the 2015 and 2023 floors on the same pre-2023 test basis shows where the 2023 change bit. Split air conditioners and split heat pumps moved up 3.6% to 7.7%; packaged air conditioners and packaged heat pumps did not move.
In the North the split air conditioner floor went from 13 SEER (2015) to the equivalent of 14 SEER (2023), a 7.7% rise. In the South the under-45,000 Btu/h floor went from 14 to 15 SEER (7.1%) and the 45,000 Btu/h and up floor from 14 to 14.5 SEER (3.6%), based on 10 CFR 430.32(c)(1) to (3) and 82 FR 1786 Table I-1.
Split heat pumps rose from 14 to 15 SEER (7.1%) and from 8.2 to 8.8 HSPF (7.3%). Packaged air conditioners and packaged heat pumps stayed at 14 SEER, with the packaged heat pump at 8.0 HSPF, so their change was 0.0%.
Minimum SEER by product class; 2023 levels as DOE stated them before translation to SEER2
Source: 10 CFR 430.32(c)(1) to (3); 82 FR 1786 Table I-1 (Jan. 6, 2017).
The North had no regional step in 2015: its split air conditioner floor stayed at 13 SEER from 2006 until the end of 2022 (76 FR 37408; 10 CFR 430.32(c)(1)). The 2023 rule was the first increase there in that period.
Install date in the South, factory date in the North: which date makes a unit legal
The same air conditioner can be legal in Ohio and illegal in Georgia on the same day. The statute applies regional standards to products installed after the effective date, while the national standard applies to products manufactured or imported after it.
42 U.S.C. 6295(o)(6)(E) sets the split: the base national standard applies to products manufactured or imported on and after the effective date, and a regional standard applies to products installed on or after it. 10 CFR 430.2 defines installation as connecting the refrigerant lines and/or electrical systems to make the unit operational.
For the 2015 step, DOE gave the South a sell-through window: it did not seek civil penalties for violations before July 1, 2016 involving units made before January 1, 2015 (81 FR 45387). DOE's regional standards page now says that policy has expired and that DOE "will strictly enforce" the regional standards.
For the 2023 step, the rule text ties Southern split air conditioners to the installation date (10 CFR 430.32(c)(6)), and DOE's current enforcement policies page, read 2026-11-02, lists no regional sell-through policy. A trade-journal summary from the International Code Council reads the rule the same way.
| Date | Step | Trigger | Citation |
|---|---|---|---|
| 2006-01-23 | 13 SEER floor for split and packaged ACs and heat pumps (heat pumps 7.7 HSPF) | Manufacture | 76 FR 37408, Table II.2 |
| 2011-06-27 | DOE direct final rule sets first regional standards for central ACs | Rule published | 76 FR 37408 |
| 2011-10-25 | 2011 direct final rule takes effect (confirmed 2011-10-31) | Effective | 76 FR 67037 |
| 2015-01-01 | Split AC 13 SEER North, 14 SEER Southeast and Southwest; heat pumps 14 SEER / 8.2 HSPF | North: manufacture; South: installation | 10 CFR 430.32(c)(1) to (3) |
| 2016-07-01 | End of DOE sell-through policy for pre-2015 units in the South; distributor records start | Enforcement discretion ends | 81 FR 45387; 10 CFR 429.142 |
| 2016-07-14 | Regional standards enforcement rule published (effective 2016-08-15) | Rule published | 81 FR 45387 |
| 2017-01-05 | Test procedure appendix M1 creates SEER2, EER2 and HSPF2 | Rule published | 82 FR 1426 |
| 2017-01-06 | Direct final rule sets the 2023 SEER2 standards | Rule published | 82 FR 1786 |
| 2017-05-08 | 2023 standards rule takes effect (confirmed 2017-05-26) | Effective | 82 FR 24211 |
| 2023-01-01 | SEER2 floors apply; appendix M1 ratings mandatory | North and heat pumps: manufacture; South split AC and Southwest packaged AC: installation | 10 CFR 430.32(c)(5) to (6) |
| 2025-01-07 | Test procedure update adds appendix M2 (SCORE and SHORE metrics, not yet required) | Rule published | 90 FR 1224 |
| 2025-07-07 | Delayed effective date of the January 2025 test procedure rule | Effective | 90 FR 21389 |
| 2025-09-09 | Controls verification enforcement provisions pushed back one year | Rule published | 90 FR 43367 |
| 2026-07-07 | Controls verification provisions in 10 CFR 429.134(k)(4) apply; DOE proposes a revised Process Rule | Applies; proposal | 10 CFR 429.134(k); 91 FR 42034 |
Dates from the cited Federal Register documents and eCFR.
Source: [11][12][13][14][15][16][17][18][19][20][10] U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); U.S. Department of Energy (Federal Register); Office of the Federal Register / U.S. Department of Energy

Heat pumps have one national floor, and in 21 jurisdictions a small split air conditioner now matches it
The minimum differs by equipment type in every one of the 51 jurisdictions, but by how much depends on the region. Heat pump floors are national and keyed to the manufacture date.
In the 30 Northern states a split heat pump must beat a split air conditioner by 0.9 SEER2 (14.3 against 13.4). In the 21 Southern jurisdictions the gap is 0.0 for units under 45,000 Btu/hr and 0.5 SEER2 for larger units (10 CFR 430.32(c)(5) to (6)).
DOE's regional standards Q&A states that heat pump standards depend on the date of manufacture, "not the date or location of installation". The regional add-ons apply to split air conditioners and, in the Southwest, packaged air conditioners (DOE Office of the General Counsel).
Shipment trends for heat pumps against furnaces are covered in the heat pump sales report; this report does not repeat them.
No state sets its own stricter air conditioner minimum, because federal law preempts it
We found no state appliance standard for central air conditioners stricter than the federal floor. Federal law blocks one unless DOE grants a waiver, and no central air conditioner waiver turned up in the Federal Register.
Under 42 U.S.C. 6297(c), once a federal standard is in effect no state regulation on the energy efficiency of that product is effective, with exceptions for a DOE waiver under 6297(d) and qualifying building codes under 6297(f)(3).
A building code may not require a covered product to exceed the federal standard unless the state holds a waiver (42 U.S.C. 6297(f)(3)(B)). States may write the federal regional standard into their own codes and may seek enforcement in federal court (42 U.S.C. 6295(o)(6)(G)).
A Federal Register search for DOE documents containing "waiver of Federal preemption" returned 8 documents on 2026-11-02. The only waiver among them covered plumbing fixtures (75 FR 80289, 2010), and California's petition on clothes washers was denied (71 FR 78157, 2006). The one central air conditioner document in the list is the 2002 standards rule, which granted no waiver.
What the regional rule asks of a contractor: 48 months of install records and a 30-day clock
The regional standard is enforced at the installer, which is unusual for an appliance rule. Contractors in 20 states and DC must keep install records, and DOE can ask for them on 30 days' notice.
Contractors and dealers must keep, for at least 48 months, the manufacturer, model, serial number, address and installation date of each split air conditioner they install in the 20 regional states and DC (10 CFR 429.142). Distributors keep records for 54 months and manufacturers for 60 months.
| Obligation | Length or amount | Who | Citation |
|---|---|---|---|
| Keep install records for each split AC (outdoor and indoor unit) and, in the Southwest, each packaged AC | 48 months | Contractors and dealers in the 21 regional jurisdictions | 10 CFR 429.142(a)(1) |
| Keep sales records for split outdoor units and packaged ACs | 54 months | Distributors (all regions) from 2016-07-01 | 10 CFR 429.142(a)(2) |
| Keep sales records | 60 months | Manufacturers and private labelers | 10 CFR 429.142(a)(3) |
| Hand records to DOE after a request | 30 calendar days | Any party asked | 10 CFR 429.144(b) |
| Replace a noncompliant unit; end user cannot be charged | At violator's cost | Party found in violation | 10 CFR 429.154(a) |
| No Notice of Violation for a single, remediated, first-time installation | 1 instance | Contractor or dealer | 10 CFR 429.146(b) |
| Maximum civil penalty per knowing violation of 10 CFR 429.102(a) | $575 | Manufacturers, private labelers and others named in 429.102(a) | 10 CFR 429.120 |
10 CFR 429.102 to 429.158, read 2026-11-02.
Source: [5][6][7][8][4] Office of the Federal Register / U.S. Department of Energy; Office of the Federal Register / U.S. Department of Energy; Office of the Federal Register / U.S. Department of Energy; Office of the Federal Register / U.S. Department of Energy; Office of the Federal Register / U.S. Department of Energy
A contractor that knowingly installs a noncompliant central air conditioner commits a violation (10 CFR 429.102(c)(3)). Replacing the unit at the violator's cost counts as remediation, and the end user cannot be charged (10 CFR 429.154). A finding of routine violation cuts the contractor off from manufacturer and distributor supply, according to DOE's enforcement page.
DOE's regional standards page, read 2026-11-02, shows headings for findings of violation and routine violation with no case entries linked beneath them. The same page still quotes a penalty of up to $440, while 10 CFR 429.120 now sets $575 per violation for prohibited acts by manufacturers and others.
For an owner, these install logs are part of the company's paper trail; anyone reviewing a Southern HVAC business, for a sale or otherwise, can ask to see them. State contractor licensing is a separate layer, covered in HVAC license requirements by state. The general steps of selling an HVAC business are on the main guide.

Since 2023: new test metrics on paper, delayed checks and no new floor
DOE has not changed the SEER2 minimums since they took effect on January 1, 2023. The later rulemakings changed how products are tested and when certain checks start.
On January 7, 2025 DOE updated appendix M1 to AHRI 210/240-2024 and added appendix M2 with two new metrics, SCORE and SHORE, which are not required until DOE adopts standards based on them (90 FR 1224). The rule's effective date was pushed back three times, to July 7, 2025 (90 FR 21389).
On September 9, 2025 DOE delayed the controls verification enforcement provisions at 10 CFR 429.134(k)(4) by one year to July 7, 2026 (90 FR 43367); the eCFR shows them applying from that date.
On July 7, 2026 DOE proposed revising the Process Rule it follows when considering new or revised efficiency standards, with comments due August 6, 2026 (91 FR 42034). That proposal does not itself change any SEER2 floor.
The refrigerant change to R-454B and the limits on new R-410A equipment are a separate EPA program, tracked in the R-410A phase-out tracker.
Counts and distributions
Share of US households under a regional split AC standard
Formula(Southeast households + Southwest households) / US households (50 states + DC) x 100
Inputs: fact rows 57 to 107 (state households), row 108 (US); region lists rows 14 and 15 (fact sheet rows)
Result: 53.0% (71,110,999 of 134,063,422 households)
Just over half of US homes are in places where a split air conditioner is judged on the day it is installed, not the day it was built.
Limitations: Households are not homes with central air; ACS 1-year sampling error applies; Puerto Rico and territories excluded.
Owner-occupied share under a regional standard
Formula(Southeast + Southwest owner-occupied households) / US owner-occupied households x 100
Inputs: registry.csv owner column; fact row 109 (fact sheet rows)
Result: 52.3% (45,810,864 of 87,511,734)
Owner-occupied homes, where replacement decisions are usually made, split almost exactly like all households.
Limitations: Tenure is not a proxy for who buys equipment in rentals.
Household-weighted federal floor for a small split air conditioner
Formula(North households x 13.4 + Southern households x 14.3) / US households
Inputs: d1, d7, fact rows 1, 9, 108 (fact sheet rows)
Result: 13.88 SEER2
A single national figure for the legal floor a typical household faces in 2025.
Limitations: Weights legal minimums, not installed efficiency.
Heat pump minus air conditioner floor, by region
Formula14.3 SEER2 (split heat pump) minus the region's split AC floor
Inputs: fact rows 1, 2, 9, 10 (fact sheet rows)
Result: North 0.9; South under 45,000 Btu/hr 0.0; South 45,000 Btu/hr and up 0.5 SEER2
In all 51 jurisdictions the split air conditioner and split heat pump floors differ for at least one size; in the South the gap disappears for small systems.
Limitations: Cooling floors only; EER2 and HSPF2 apply on top.
2015 to 2023 change on the pre-2023 test
Formula(2023 level on old test minus 2015 level) / 2015 level x 100
Inputs: fact rows 16 and 18 (fact sheet rows)
Result: Split AC North 7.7%; South under 45,000 Btu/h 7.1%; South 45,000 and up 3.6%; split heat pump 7.1% (SEER) and 7.3% (HSPF); packaged 0.0%
The 2023 step was a real tightening for split systems and none for packaged units.
Limitations: Uses DOE's stated old-test equivalents; individual products can rate differently.
Implied SEER2 to SEER ratio of DOE's translated floors
FormulaSEER2 level / old-test SEER level, per standard
Inputs: fact rows 1, 2, 9, 10, 18 (fact sheet rows)
Result: 0.952 to 0.957 for cooling floors; 0.838 to 0.852 for heating floors
Explains why 13.4 SEER2 matches the old 14 SEER, not 13.
Limitations: Not a conversion factor for individual products.
Key findings
- Split air conditioners made on or after 2023-01-01 must reach at least 13.4 SEER2 nationwide, the full requirement in the 30 Northern states (10 CFR 430.32(c)(5), read 2026-11-02).[1]
- In the Southeast and Southwest, split air conditioners installed on or after 2023-01-01 need 14.3 SEER2 under 45,000 Btu/hr and 13.8 SEER2 at 45,000 Btu/hr and up (10 CFR 430.32(c)(6)).[1]
- Southwest split air conditioners also need 11.7 EER2 (under 45,000 Btu/hr) or 11.2 EER2 (larger), or 9.8 EER2 at 15.2 SEER2 and above; Southwest packaged air conditioners need 10.6 EER2.[1]
- Split heat pumps carry a national floor of 14.3 SEER2 and 7.5 HSPF2, and packaged heat pumps 13.4 SEER2 and 6.7 HSPF2, as of 2026.[1]
- 71.1 million US households, 53.0% of the 2025 total, live in the 21 jurisdictions where split air conditioner floors are checked at installation (ACS 2025 B25003).[30][1]
- The Southeast holds 38.8% of US households, the Southwest 14.2% and the North 47.0% (ACS 2025).[30]
- The household-weighted legal floor for a split air conditioner under 45,000 Btu/hr was 13.88 SEER2 in 2025.[30][1]
- DOE stated the 2023 floors on the old test as 14, 15 and 14.5 SEER before restating them as 13.4, 14.3 and 13.8 SEER2 (82 FR 1786, 2017).[14]
- DOE reported a 15% reduction from HSPF to HSPF2 for split and packaged heat pumps caused by the test change, not by product changes (82 FR 1786).[14]
- On the same pre-2023 test, the Northern split air conditioner floor rose 7.7% in 2023 (13 to 14 SEER), the first increase there since 2006.[1][11][14]
- Contractors in 20 regional states and DC must keep split air conditioner install records for at least 48 months (10 CFR 429.142).[5]
- The maximum civil penalty under 10 CFR 429.120 is $575 per violation in 2026, while DOE's regional standards web page still cites $440.[4][27]
- A Federal Register search on 2026-11-02 found 8 DOE documents mentioning a waiver of Federal preemption; none grants one for central air conditioners.[23][21][22]
Executive summary
- SEER2 minimums vary by DOE region, not by individual state: 30 Northern states, 17 Southeastern jurisdictions (16 states plus DC) and 4 Southwestern states (10 CFR 430.32(c)(6)).
- Split air conditioners need 13.4 SEER2 in the North and 14.3 SEER2 (13.8 at 45,000 Btu/h and up) in the Southeast and Southwest; the Southwest also sets EER2 floors.
- Split heat pumps need 14.3 SEER2 and 7.5 HSPF2 everywhere; packaged heat pumps 13.4 SEER2 and 6.7 HSPF2; packaged air conditioners 13.4 SEER2.
- In 2025, 53.0% of US households (ACS) lived in the regional zones where the floor applies on the installation date.
- On DOE's own pre-2023 test basis, the 2023 step raised split air conditioner floors by 3.6% to 7.7% and left packaged units unchanged.
- No state has a stricter central air conditioner standard we could find; federal law preempts state efficiency rules absent a DOE waiver.
- Contractors in 20 states and DC must keep install records for 48 months and produce them within 30 days of a DOE request.
Questions people ask
What is the minimum SEER2 in my state?
In the 30 Northern states a split air conditioner needs 13.4 SEER2. In the 16 Southeastern states, DC and the 4 Southwestern states it needs 14.3 SEER2 under 45,000 Btu/h or 13.8 SEER2 at 45,000 Btu/h and up, plus EER2 floors in the Southwest. Split heat pumps need 14.3 SEER2 everywhere (10 CFR 430.32(c), 2026). The registry below lists each state.
Can I still install a 13 SEER air conditioner?
In the North, the federal floor is tied to the manufacture date, so a split air conditioner made before 2023-01-01 that met the 13 SEER standard of that time is not barred by DOE's efficiency rule. In the Southeast and Southwest, no: a split unit installed on or after 2023-01-01 must meet 14.3 or 13.8 SEER2, and 13 SEER was already below the 14 SEER Southern floor from 2015. Refrigerant rules are separate; see the R-410A phase-out tracker.
What is the difference between SEER and SEER2?
SEER2 comes from DOE's appendix M1 test, mandatory for ratings from 2023-01-01 (82 FR 1426). The same equipment rates lower on SEER2; DOE restated 14 SEER as 13.4 SEER2 and 15 SEER as 14.3 SEER2 without assuming any design change (82 FR 1786).
Which states require 15 SEER?
No federal floor has been written in plain SEER since 2023. The 14.3 SEER2 floor that applies to small split air conditioners in the 21 Southern jurisdictions, and to split heat pumps everywhere, is DOE's restatement of 15 SEER on the old test (82 FR 1786, Table I-1).
Frequently asked questions
Who sets SEER2 minimums, the state or the federal government?
The U.S. Department of Energy, under 10 CFR 430.32(c). Federal law preempts state efficiency standards for central air conditioners unless DOE grants a waiver (42 U.S.C. 6297), and we found no such waiver as of 2026-11-02.
Which states are in the Southeast region?
Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, South Carolina, Tennessee, Texas, Virginia and DC, plus Puerto Rico and the U.S. territories (10 CFR 430.32(c)(6)).
Which states are in the Southwest region?
Arizona, California, Nevada and New Mexico. These 4 states hold 14.2% of US households (ACS 2025).
Is Delaware in the North or the Southeast?
The Southeast. 10 CFR 430.32(c)(6) lists Delaware and Maryland in the Southeast region, so split air conditioners installed there need 14.3 SEER2 below 45,000 Btu/h.
Do regional standards apply to heat pumps?
No. Split heat pumps need 14.3 SEER2 and 7.5 HSPF2 everywhere, judged by the date of manufacture, according to 10 CFR 430.32(c)(5) and DOE's regional standards Q&A.
What EER2 is required in Arizona, California, Nevada and New Mexico?
11.7 EER2 for split air conditioners under 45,000 Btu/h and 11.2 EER2 for larger ones, or 9.8 EER2 if the certified SEER2 is 15.2 or more; packaged air conditioners need 10.6 EER2 (10 CFR 430.32(c)(6)).
Does the 45,000 Btu/h line matter in the North?
No. Both capacity classes of split air conditioner share the 13.4 SEER2 floor in the North; the 45,000 Btu/h split only lowers the Southern floor from 14.3 to 13.8 SEER2.
Can a Southern contractor replace only the outdoor unit?
DOE's 2018 Q&A says yes, if the outdoor unit model is certified in at least one combination that meets the regional standard and is not certified in any combination below it. The 2023 rule keeps the test that any model with a certified combination below the regional level cannot be installed there (10 CFR 430.32(c)(6)(ii)).
How long must contractors keep install records?
At least 48 months from installation in the 20 regional states and DC, and DOE can demand them within 30 calendar days (10 CFR 429.142 and 429.144).
Has DOE announced new SEER2 minimums after 2023?
No new floors as of 2026-11-02. DOE's 2025 and 2026 actions changed test procedures (90 FR 1224), delayed enforcement provisions to 2026-07-07 (90 FR 43367) and proposed process changes (91 FR 42034).
Download the data
Every table in this report is available as a CSV under CC BY 4.0. The fact sheet lists each value with its source URL and access date.
- derived_metrics.csv (CSV)
- fact_sheet.csv (CSV)
- SEER2 requirements by state: federal minimums registry (CSV)
- Federal minimums for central air conditioners and heat pumps by DOE region (from 2023-01-01) (CSV)
- Timeline of federal central air conditioner standards and enforcement dates, 2006 to 2026 (CSV)
- DOE's restatement of the 2023 floors from the old test to appendix M1 (CSV)
- Households by DOE efficiency region, 2025 (CSV)
- All 50 states and DC ranked by 2025 households, with DOE region and split AC floor (CSV)
- Records, deadlines and penalties under the regional standards enforcement rules (CSV)
For journalists and researchers
If you cite only a few, cite these
- 53.0% of US households live where split air conditioner SEER2 floors apply at installation (ACS 2025; 10 CFR 430.32(c)(6)).[30][1]
- 13.4 SEER2 North; 14.3 SEER2 (13.8 at 45,000 Btu/h and up) Southeast and Southwest; heat pumps 14.3 SEER2 and 7.5 HSPF2 nationwide (10 CFR 430.32(c), 2026).[1]
- The household-weighted federal floor for a small split air conditioner was 13.88 SEER2 in 2025.[30][1]
Most quotable statistics
- In 2025, 53.0% of US households (71.1 million) lived in the 21 jurisdictions where a split air conditioner must meet a higher SEER2 floor on the day it is installed (ACS 2025; 10 CFR 430.32).[30][1]
- Split air conditioners need 13.4 SEER2 in the 30 Northern states and 14.3 SEER2 below 45,000 Btu/h in the Southeast and Southwest, as of 2026 (10 CFR 430.32(c)).[1]
- Split heat pumps need 14.3 SEER2 and 7.5 HSPF2 in every state in 2026 (10 CFR 430.32(c)(5)).[1]
- DOE restated the 2023 floor of 14 SEER as 13.4 SEER2 and 15 SEER as 14.3 SEER2, saying the translation assumed no change in product design (82 FR 1786, 2017).[14]
- The household-weighted federal floor for a small split air conditioner was 13.88 SEER2 in 2025.[30][1]
- Measured on the old test, the 2023 standard raised the Northern split air conditioner floor 7.7% and left packaged units unchanged (10 CFR 430.32; 82 FR 1786).[1][14]
Press summary
Federal SEER2 minimums for central air conditioners differ by Department of Energy region rather than by state, and 53.0% of US households (71.1 million in the Census Bureau's 2025 American Community Survey) live in the 21 Southeastern and Southwestern jurisdictions where a split air conditioner must reach 14.3 SEER2, or 13.8 at 45,000 Btu/h and up, on the day it is installed. The 30 Northern states require 13.4 SEER2 based on the date of manufacture, and split heat pumps need 14.3 SEER2 and 7.5 HSPF2 everywhere, according to 10 CFR 430.32 as checked on 2026-11-02 by the HVAC Business Brokers Research Desk. Measured on DOE's older test, the 2023 rule raised split air conditioner floors 3.6% to 7.7%, left packaged units unchanged, and no state has a stricter standard because federal law preempts state efficiency rules.
Suggested headlines
- 53% of US homes sit where air conditioner efficiency is checked at installation
- SEER2 by state: 30 states at 13.4, 21 jurisdictions at 14.3
- The 2023 SEER2 rule tightened split systems 7.7% in the North and skipped packaged units
- Why 13.4 SEER2 is not weaker than 14 SEER: DOE's own numbers
- No state sets an air conditioner efficiency floor above the federal one
How to cite this report
HVAC Business Brokers. (2026). SEER2 Requirements by State: Federal Minimums for Air Conditioners and Heat Pumps (2026). Retrieved from https://sell-my-hvac-business.com/research/seer2-requirements-by-state/
Reuse license
Data and tables are licensed CC BY 4.0. Attribution: “Source: HVAC Business Brokers, SEER2 Requirements by State: Federal Minimums for Air Conditioners and Heat Pumps (2026)” with a link to this page.
Reproduce this analysis
Every figure comes from the files below. The scripts that pulled and computed them are kept with the report and can be re-run.
| Dataset | Publisher | Source | Query or filter | Rows used | Retrieved |
|---|---|---|---|---|---|
| eCFR 10 CFR 430.32, 430.2, 429.102, 429.120, 429.134, 429.142, 429.144, 429.146, 429.154, 429.158 | Office of the Federal Register (eCFR versioner API) | File or endpoint | date 2026-10-29 (title 10 up to date as of that day); one call per section with part and section parameters; gzip required | 1 section per call; 10 sections saved in raw/ | 2026-11-02 |
| Federal Register documents (76 FR 37408, 76 FR 67037, 81 FR 45387, 82 FR 1426, 82 FR 1786, 82 FR 24211, 90 FR 1224, 90 FR 21389, 90 FR 43367, 91 FR 42034) | Office of the Federal Register API | File or endpoint | document JSON plus raw_text_url for each document number; search with agency energy-department and term 'central air conditioners and heat pumps' | 296 search hits read by title; 10 documents used | 2026-11-02 |
| American Community Survey 2025 1-year, B25003 | U.S. Census Bureau | File or endpoint | GEO_ID 0400000US + 2-digit FIPS for 50 states and DC, and 0100000US; columns B25003_E001 to E003 | 51 state rows plus 1 national row used of 52 state-level rows (Puerto Rico dropped) | 2026-11-02 |
| United States Code, 42 U.S.C. 6295, 6297, 6302, 6303 | U.S. Government Publishing Office (govinfo) | File or endpoint | most recent edition (2024), HTML | 4 sections saved; 6295(o)(6) and 6297(c), (d), (f) used | 2026-11-02 |
Data quality and exclusions
- ACS file: 52 state-level rows; 1 row (Puerto Rico) dropped so the totals cover the 50 states and DC; non-state geographies other than the national row were ignored.
- Check: the sum of the 51 state household estimates (134,063,422) equals the national row exactly, so no rows were lost.
- Region coding: 17 Southeast and 4 Southwest names asserted against the eCFR footnote text; the remaining 30 states coded North by elimination.
- Federal Register search: 296 hits on 'central air conditioners and heat pumps' screened by title; 10 rules used, the rest concern other products or waivers for single manufacturers.
- DOE pages: 3 energy.gov URLs returned not-found errors and 1 returned a 2015 PDF on a different topic; they are listed in excluded.md and not cited.
Methodology
Selection: the registry is coded from the official text of 10 CFR 430.32(c) and Part 429 as published on eCFR (up to date as of 2026-10-29) and read on 2026-11-02, from Federal Register final rules, from 42 U.S.C. 6295 and 6297 (United States Code 2024 edition via govinfo), and from DOE Office of the General Counsel pages. Trade-press and manufacturer pages were used only to check what competing pages say.
Coding: each of the 50 states and DC is assigned to the North, Southeast or Southwest using the state lists in the footnotes to 10 CFR 430.32(c)(6); the build script asserts each name against the downloaded eCFR text. Every registry row carries the CFR citation, the eCFR URL, the date checked (2026-11-02) and a confidence field; all 51 rows are 'clear text' because the regulation names each state.
State standards: we searched the Federal Register API for DOE documents containing 'waiver of Federal preemption' and read the statute's preemption and building-code exceptions. We did not open each state's appliance code; a state rule stricter than the federal floor would be preempted unless DOE granted a waiver, and none for central air conditioners was found.
Households: counts are occupied housing units from the ACS 2025 1-year table-based summary file (table B25003), released 2026-10-29. The national figure equals the sum of the 51 state rows; Puerto Rico is excluded even though the regulation places it in the Southeast.
Derived metrics: regional sums and shares, the household-weighted floor, the heat pump to air conditioner gaps, the implied SEER2 to SEER ratios and the 2015 to 2023 changes are computed in scripts/build_tables.py and listed with formulas in derived_metrics.csv. Conflicts: where DOE's 2015-era web page and the current CFR differ (penalty amount), the CFR text is used and the difference is reported.
Limitations and update: the registry is checked once for this edition and will be rechecked when DOE publishes a new standard or at least every six months. Last update 2026-11-02. Readers who want an estimate of their own company's value can use the form at the valuation page.
This report presents published data with its limitations. It is not legal, financial or investment advice.
Sources, ranked by quality
Tier 1: primary and official sources (31)
- [1] Office of the Federal Register / U.S. Department of Energy. 10 CFR 430.32(c), energy conservation standards for central air conditioners and heat pumps (eCFR, up to date as of 2026-10-29). In force 2026. Accessed 2026-11-02.
- [2] Office of the Federal Register / U.S. Department of Energy. 10 CFR 430.2, definitions (installation of a central air conditioner; central air conditioner). In force 2026. Accessed 2026-11-02.
- [3] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.102, prohibited acts and violations of regional standards. In force 2026. Accessed 2026-11-02.
- [4] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.120, maximum civil penalty. In force 2026. Accessed 2026-11-02.
- [5] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.142, records retention for regional standards. In force 2026. Accessed 2026-11-02.
- [6] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.144, records request. In force 2026. Accessed 2026-11-02.
- [7] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.146 and 429.148, notice of violation and routine violator. In force 2026. Accessed 2026-11-02.
- [8] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.154, remediation. In force 2026. Accessed 2026-11-02.
- [9] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.158, product determined noncompliant with regional standards. In force 2026. Accessed 2026-11-02.
- [10] Office of the Federal Register / U.S. Department of Energy. 10 CFR 429.134(k), product-specific enforcement provisions for central air conditioners and heat pumps. In force 2026. Accessed 2026-11-02.
- [11] U.S. Department of Energy (Federal Register). Energy Conservation Standards for Residential Furnaces and Residential Central Air Conditioners and Heat Pumps, direct final rule, 76 FR 37408. Published 2011-06-27. Accessed 2026-11-02.
- [12] U.S. Department of Energy (Federal Register). Confirmation of effective and compliance dates, 76 FR 67037. Published 2011-10-31. Accessed 2026-11-02.
- [13] U.S. Department of Energy (Federal Register). Enforcement of Regional Standards for Central Air Conditioners, final rule, 81 FR 45387. Published 2016-07-14. Accessed 2026-11-02.
- [14] U.S. Department of Energy (Federal Register). Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps, direct final rule, 82 FR 1786. Published 2017-01-06. Accessed 2026-11-02.
- [15] U.S. Department of Energy (Federal Register). Confirmation of effective and compliance dates, 82 FR 24211. Published 2017-05-26. Accessed 2026-11-02.
- [16] U.S. Department of Energy (Federal Register). Test Procedures for Central Air Conditioners and Heat Pumps, final rule (appendix M1), 82 FR 1426. Published 2017-01-05. Accessed 2026-11-02.
- [17] U.S. Department of Energy (Federal Register). Test Procedure for Central Air Conditioners and Heat Pumps, final rule (appendix M2), 90 FR 1224. Published 2025-01-07. Accessed 2026-11-02.
- [18] U.S. Department of Energy (Federal Register). Further delay of effective date, 90 FR 21389. Published 2025-05-20. Accessed 2026-11-02.
- [19] U.S. Department of Energy (Federal Register). One-year delay of controls verification enforcement provisions, 90 FR 43367. Published 2025-09-09. Accessed 2026-11-02.
- [20] U.S. Department of Energy (Federal Register). Proposed update to the Process Rule for new or revised standards, 91 FR 42034. Published 2026-07-07. Accessed 2026-11-02.
- [21] U.S. Department of Energy (Federal Register). Waiver of Federal preemption for state water-use rules on showerheads, faucets, water closets and urinals, 75 FR 80289. Published 2010-12-22. Accessed 2026-11-02.
- [22] U.S. Department of Energy (Federal Register). Denial of California Energy Commission petition for exemption from Federal preemption (clothes washers), 71 FR 78157. Published 2006-12-28. Accessed 2026-11-02.
- [23] Office of the Federal Register. Federal Register API search: DOE documents containing "waiver of Federal preemption". All years to 2026-11-02. Accessed 2026-11-02.
- [24] Office of the Federal Register. Federal Register API search: DOE documents containing "central air conditioners and heat pumps". All years to 2026-11-02. Accessed 2026-11-02.
- [25] U.S. Government Publishing Office (govinfo), United States Code 2024 edition. 42 U.S.C. 6295, energy conservation standards (including (o)(6) regional standards). 2024 edition. Accessed 2026-11-02.
- [26] U.S. Government Publishing Office (govinfo), United States Code 2024 edition. 42 U.S.C. 6297, effect on other law (Federal preemption). 2024 edition. Accessed 2026-11-02.
- [27] U.S. Department of Energy, Office of the General Counsel. Regional Standards Enforcement. Page read 2026-11-02. Accessed 2026-11-02.
- [28] U.S. Department of Energy, Office of the General Counsel. Regional Standards Enforcement: Q&As (dated 2018-02-27). 2018. Accessed 2026-11-02.
- [29] U.S. Department of Energy, Office of the General Counsel. Enforcement Policies and Statements. Page read 2026-11-02. Accessed 2026-11-02.
- [30] U.S. Census Bureau. American Community Survey 2025 1-year, table B25003 (tenure), table-based summary file. 2025. Accessed 2026-11-02.
- [31] U.S. Census Bureau. ACS data releases page (2025 1-year estimates released 2026-10-29). 2025. Accessed 2026-11-02.
Tier 3: journalism and expert commentary (1)
- [32] International Code Council, Building Safety Journal. 2023 Efficiency Requirements for Air Conditioning Systems: What You Need to Know. 2023 standards. Accessed 2026-11-02.